29 March 2018
Multiple vulnerabilities identified in the Modicon family of industrial controllersUS CERT has published an advisory on vulnerabilities in the Modicon family of industrial controllers by Schneider Electric.
Filter
Filter
29 March 2018
Multiple vulnerabilities identified in the Modicon family of industrial controllersUS CERT has published an advisory on vulnerabilities in the Modicon family of industrial controllers by Schneider Electric.
26 March 2018
Improper Input Validation vulnerability in Siemens industrial devicesA vulnerability that could cause a denial-of-service condition has been identified in Siemens industrial solutions. The vulnerability can only be exploited if the attacker is located in the same Ethernet segment as the targeted device
26 March 2018
Serious vulnerability identified in Beckhoff TwinCAT PLC software solutionVulnerability in kernel drivers of Beckhoff TwinCAT 2 and 3.1 PLC software solutions for PLCs could allow local attackers to escalate privileges on target systems
01 March 2018
Siemens industrial solutions are affected by vulnerabilities in Intel ME, SPS and TXE technologies28 industrial solutions by Siemens are affected by vulnerabilities in Intel ME, SPS and TXE technologies. The vendor has released patches for all of these products and made these patches available on its website
27 February 2018
OMG botnet turns infected devices into proxy serversA new variant of the Mirai botnet can set up proxy servers on infected IoT devices
22 February 2018
3.3% of ICS computers attacked by miners during the past yearKaspersky Lab has recorded an increase in the number of attacks involving cryptocurrency miners on the infrastructure of industrial enterprises, which started in September 2017. Miners can interfere with industrial process control and threaten process stability.
22 February 2018
Vulnerabilities in GE D60 Line Distance Relay devicesCritical vulnerabilities have been identified in General Electric D60 Line Distance Relay devices. The vulnerabilities could allow attackers to execute code on vulnerable systems.
22 February 2018
Critical vulnerability in WAGO PFC200 controllers closedWAGO has closed a critical vulnerability (improper authentication) in its PFC200 Series PLCs.
29 January 2018
Vulnerability in Nari PCS-9611 relaysAn improper input validation vulnerability has been identified in the Nari PCS-9611 protection relay. Although an exploit for the vulnerability exists, the vendor has so far not commented on the problem.
12 January 2018
Industrial solutions may be affected by Spectre and Meltdown vulnerabilitiesVulnerabilities in Intel, ARM64 and AMD processors allow unauthorized access to virtual memory contents. Vulnerable devices include industrial equipment.